Zero emission valve

Everything about zero emission valve for industry

The technology behind zero emission valve

A zero emission valve is qualified to the strictest fugitive emission classes, where leakage along the stem is reduced to a level that is barely measurable. Anyone looking into zero emission valve quickly runs into a choice that goes beyond picking a catalogue number. Once zero emission valve is correctly specified it disappears from the fault list, and that is exactly the intention. API 609 is the construction standard for butterfly valves and separates category A for concentric designs from category B for offset and high performance designs. API 607 describes the fire test for quarter turn valves with a non metallic seat, where the valve must stay within a defined leakage limit after fire exposure. The German TA-Luft is not a standard but an administrative directive, and the 2021 revision explicitly refers to the measurement method from ISO 15848 for valves. How zero emission valve behaves under varying load says more about the quality of the selection than behaviour under steady load. The balance between required tightness and available operating force is a recurring tension on zero emission valve. With zero emission valve the seat is the component that determines performance, and the body is rarely the limiting factor. Fugitive emission is the uncontrolled leak along the stem and the flanged joints, and in a process plant valves are by far the largest source. ISO 15848 defines how that leakage is measured, with part 1 as a type test on a prototype and part 2 as a production test on a delivered valve. We approach zero emission valve from the question of what the plant has to do, not from the question of what happens to be in stock.
Schroeder Fluid loop test system

Material, seat and construction on zero emission valve

Zero emission is a marketing shorthand, because no mechanical seal is genuinely at zero, and the honest term is class A to ISO 15848. Operating conditions govern the service life of zero emission valve far more strongly than the nominal figures on a datasheet. On zero emission valve we always check the full operating envelope, including start up and shutdown. Reaching that level usually requires either a bellows seal or a very high grade live loaded packing system. The packing set is the decisive component in emission control, because that is where stem movement takes place and where the leak path is created. ISO 15848-1 distinguishes classes A, B and C, where class A is the strictest and in practice is only achieved with a bellows seal or a very high grade packing. API 641 is the American counterpart for emission testing of quarter turn valves and applies a limit of one hundred ppmv across the full test cycle. Qualification always states a number of cycles, and a valve that only performs when new is of little practical use. Remember that flange gaskets and connections also count in an emission measurement, not only the stem. A low emission class often comes with higher operating torque, because the packing is preloaded more tightly. For zero emission valve this means that construction and operating conditions cannot be judged separately. In practice we find that most failures around zero emission valve come not from the material but from a wrong assumption during selection.

Applications of zero emission valve in industry

These valves are specified in chemicals, petrochemicals and in hydrogen and ammonia plants where permit limits are tight. In VOC bearing processes the emission performance of the valves determines a directly measurable share of total plant emissions. In chemicals and petrochemicals emission control is not optional, because the permit imposes limits that are checked at every measurement round. Demand for zero emission valve reaches us mainly from projects where the standard range falls short. We supply zero emission valve both for new build and for replacement within existing installations. On project supply we record per position which execution of zero emission valve was delivered, including materials and tests. On replacement we always check the existing installation dimensions for zero emission valve, so the pipework can stay untouched. In hydrogen and ammonia service emission weighs even heavier because of small molecule size and safety risk. Our market is project driven and international, and we deliver worldwide to installers, EPC contractors and end users. What defines us is that we would rather spend an extra half hour on the specification than ship the wrong valve that comes back two months later. We see demand for zero emission valve rising in hydrogen and ammonia projects, where tightness requirements are high. For zero emission valve the sector determines which documentation and tests belong with the delivery.
STRIKO Valves

Specifying zero emission valve correctly

The cleaning and flushing procedure counts too on zero emission valve, because it can be more aggressive than the process itself. The number of cycles in the qualification matters at least as much as the class itself, because a valve that no longer seals after a thousand strokes fails in practice. We advise writing the emission requirement into the basic specification rather than testing against it afterwards, because a later change is always more expensive. With an emission specification we first check which class and which test medium the project demands, because helium and methane carry different limits. Where zero emission valve forms part of a safety function we record the fail position and required stroking time explicitly. If a simpler type will do the job, we say so on zero emission valve, even when that means a smaller order. Where there is doubt about zero emission valve we quote two executions side by side, with the trade offs stated explicitly. A live loaded packing system with disc springs maintains preload through temperature cycling and extends the interval between adjustments. Graphite is the usual choice at high temperature, while PTFE and modified PTFE perform better at low temperature and against chemical attack. If you have an existing tag plate or serial number, send it along, because that lets us work directly from the original configuration. Standardising across several positions makes zero emission valve simpler in maintenance and in spare parts management. We never recommend a heavier execution of zero emission valve than needed, because over specification only raises price and lead time.
TOSV butterfly valve

Zero emission valve supplied with technical advice

We think along on the spare parts strategy for zero emission valve, so critical positions stay covered. Our customers work in chemicals, petrochemicals, pharmaceuticals, power generation, offshore and in hydrogen and ammonia projects. For zero emission valve you can come to Dutch Valve Vision for the selection, the delivery and the support afterwards. For repeat orders of zero emission valve we record the configuration, so a follow up delivery is identical to the first. Even when the specification for zero emission valve is not yet finalised, you can bring the question to us. We keep spare parts and overhaul kits mapped per project, so that a breakdown does not start with a search from scratch. A tag plate with project data belongs with zero emission valve as standard where the project requires it. On zero emission valve we make sure the chosen execution demonstrably meets the stated standards rather than merely looking plausible on paper. Documentation on zero emission valve has to be the kind a buyer or inspector accepts without discussion. Dutch Valve Vision stays available after delivery of zero emission valve for technical questions and for parts. We supply zero emission valve as a loose product or as a fully assembled unit with actuator and accessories. Requests can be submitted by phone on +31 (0)70-2210560, by e-mail at sales@dutchvalvevision.com or through the contact form on our website.
Striko mengers en breekplaten

Frequently asked questions about zero emission valve

What exactly does zero emission valve mean?
A zero emission valve is qualified to the strictest fugitive emission classes, where leakage along the stem is reduced to a level that is barely measurable. The packing set is the decisive component in emission control, because that is where stem movement takes place and where the leak path is created. ISO 15848 defines how that leakage is measured, with part 1 as a type test on a prototype and part 2 as a production test on a delivered valve. The German TA-Luft is not a standard but an administrative directive, and the 2021 revision explicitly refers to the measurement method from ISO 15848 for valves. In most projects zero emission valve turns out to be less standard than it first appears. On zero emission valve we include start up and shutdown, because that is where the heaviest loading occurs. With zero emission valve the difference between a good and a mediocre solution often sits in details that do not show on a drawing. We think along from the basic specification through to the tag plate, and supply documentation that a buyer or inspector accepts without discussion.
API 607 describes the fire test for quarter turn valves with a non metallic seat, where the valve must stay within a defined leakage limit after fire exposure. API 609 is the construction standard for butterfly valves and separates category A for concentric designs from category B for offset and high performance designs. Qualification always states a number of cycles, and a valve that only performs when new is of little practical use. Fugitive emission is the uncontrolled leak along the stem and the flanged joints, and in a process plant valves are by far the largest source. Our experience with zero emission valve comes from projects in chemicals, power generation, technical gases and offshore. On zero emission valve we prefer a well founded answer to a fast one that turns out to be wrong later. That principle explains why zero emission valve behaves differently from a standard execution under heavier duty. What defines us is that we would rather spend an extra half hour on the specification than ship the wrong valve that comes back two months later.
Zero emission is a marketing shorthand, because no mechanical seal is genuinely at zero, and the honest term is class A to ISO 15848. A live loaded packing system with disc springs maintains preload through temperature cycling and extends the interval between adjustments. API 641 is the American counterpart for emission testing of quarter turn valves and applies a limit of one hundred ppmv across the full test cycle. Reaching that level usually requires either a bellows seal or a very high grade live loaded packing system. That makes zero emission valve a subject where discussion up front pays for itself in operation. For zero emission valve a good specification up front is cheaper than a correction afterwards. We regularly see that a small change in the execution of zero emission valve makes a large difference to maintenance frequency. Dutch Valve Vision supplies special valves for special applications from its base in Monster, the Netherlands, with QUADAX and PRUSS as the core brands in the programme.
What should I watch technically on zero emission valve?
In chemicals and petrochemicals emission control is not optional, because the permit imposes limits that are checked at every measurement round. These valves are specified in chemicals, petrochemicals and in hydrogen and ammonia plants where permit limits are tight. In hydrogen and ammonia service emission weighs even heavier because of small molecule size and safety risk. In VOC bearing processes the emission performance of the valves determines a directly measurable share of total plant emissions. The answer on zero emission valve depends strongly on operating conditions, which is why we always ask for those first. We always explain why we arrive at a particular recommendation on zero emission valve, so you can follow the reasoning yourself. Our customers use zero emission valve in positions where a failure has immediate consequences for production. Our market is project driven and international, and we deliver worldwide to installers, EPC contractors and end users.
Please also state the connection standard, the required leakage class and any project requirements such as NACE, PED or ATEX. We come back with a proposal that explains why we recommend a particular execution, including the alternatives we considered. Documentation such as material certificates, test reports and declarations is supplied as standard, matched to what the project requires. For shutdowns and turnarounds we look at accelerated routes, and in those cases we are honest up front about what is and is not achievable. If you are unsure about this on zero emission valve, we are glad to put the question alongside the actual process data. The answer to this question on zero emission valve changes as soon as the medium or the temperature changes. Our specialists are happy to discuss zero emission valve on the basis of your P&ID, your datasheet or simply a photograph of the situation. Send us your DN, pressure class, medium and temperature at sales@dutchvalvevision.com, or call +31 (0)70-2210560 to speak to a specialist.
On repeat orders we record the configuration, so a follow up delivery is identical to the first and installation holds no surprises. Lead times depend on the execution, because a standard size from a running series behaves very differently from a valve in an exotic alloy with NACE certification. We keep spare parts and overhaul kits mapped per project, so that a breakdown does not start with a search from scratch. We quote a realistic lead time rather than an optimistic one, because a missed delivery date costs more than an extra week in the planning. This is one of the points on zero emission valve where suppliers differ most clearly from one another. The answer on zero emission valve depends strongly on operating conditions, which is why we always ask for those first. We record which execution of zero emission valve was delivered, so a follow up delivery or spare part matches exactly later on. Alongside QUADAX and PRUSS we represent Pibiviesse, Schroeder, Striko, Malbranque, Daume, FluoroSeal and Guichon, so we can select the right brand for each project.
A P&ID, a datasheet or even a photograph of the existing installation often helps us faster than a long description. If you have an existing tag plate or serial number, send it along, because that lets us work directly from the original configuration. For an accurate quotation we need the nominal diameter, the pressure class, the medium, the operating temperature and the required actuation. We come back with a proposal that explains why we recommend a particular execution, including the alternatives we considered. We always explain why we arrive at a particular recommendation on zero emission valve, so you can follow the reasoning yourself. That makes zero emission valve a subject where discussion up front pays for itself in operation. On zero emission valve we come back with a proposal that explains why we recommend a particular execution. Requests can be submitted by phone on +31 (0)70-2210560, by e-mail at sales@dutchvalvevision.com or through the contact form on our website.