The cleaning and flushing procedure counts too on control valve, because it can be more aggressive than the process itself. Oversizing is the most common mistake, because an oversized valve only controls in the first few degrees of travel and wears there rapidly. On every selection we check for cavitation, flashing and sound level, because those three determine trim life. Correct sizing starts from the full operating envelope, so minimum, normal and maximum flow with their corresponding pressures. For control valve we ask as standard for DN, pressure class, medium, temperature and required actuation. Standardising across several positions makes control valve simpler in maintenance and in spare parts management. On control valve we check that the actuator is sized on torque at maximum differential pressure and not on an average value. Where control valve forms part of a safety function we record the fail position and required stroking time explicitly. During overhaul we measure trim and seat and advise whether reworking is sufficient or replacement works out cheaper. A control valve that audibly whistles or vibrates is telling you something about the selection, and that signal should be solved rather than insulated away. For an accurate quotation we need the nominal diameter, the pressure class, the medium, the operating temperature and the required actuation. Where there is doubt about control valve we quote two executions side by side, with the trade offs stated explicitly. The right choice around control valve starts with a full set of process data rather than with a request for a price.